We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Data Prediction.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Data Prediction - List of Manufacturers, Suppliers, Companies and Products

Data Prediction Product List

1~2 item / All 2 items

Displayed results

OIT prediction based on accelerated test data of polyamide 6 powder chemiluminescence.

Explore the reaction model formula for oxidation induction reactions using thinning data with TKsd software!

This document is a technical note explaining the OIT prediction based on the chemiluminescence accelerated test data for polyamide 6 powder (without added antioxidants). Using the TKsd software, we explored the reaction model equations for the oxidation induction reaction based on the downsampled data (accelerated test data). The resulting reaction model equations were divided into two stages: Equation A and Equation B. What do each of the reaction model equations A and B represent? Please take a look. 【Published Data (Excerpt)】 ■ Conducted accelerated tests on multiple test specimens over a long period using several constant temperature baths. ■ Reaction rate curves under isothermal conditions of 60-80°C from CL data at 0.2-0.8 K/min. ■ Reaction rate curves downsampled to 1/150 from the predicted reaction rate curves. ■ Explored reaction model equations from the downsampled reaction rate curves under isothermal conditions of 60-80°C. ■ Created a log-log plot with the Y-axis as CL intensity and the X-axis as time from the reaction model equations. *For more details, please download the PDF or feel free to contact us.

  • Business Intelligence and Data Analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

OIT prediction based on Chemiluminescence data of Polyamide 6 powder.

Predictive analysis of OIT values using heating measurement data up to 190℃!

This document is a technical note explaining the OIT prediction based on Chemiluminescence data for polyamide 6 powder (without added antioxidants). Using heating measurement data up to 190°C (35°C below the melting point), where PA6 is in a state of slight melting of crystalline and amorphous parts, the OIT value is predicted. It was found that the oxidation induction time (OIT) can be predicted in the range of 90°C to 230°C from the heating measurement data at 0.2, 0.4, and 0.8 K/min. For details, please refer to the published catalog. 【Published Data (Excerpt)】 ■ CL strength signal data from 50 to 250°C (0.8 K/min) ■ Selection of appropriate peak integration range ■ Standardization of CL strength curves at 0.2 to 0.8 K/min with a peak integration value of 8.28E8 cts/g ■ Peak integration curve of heating rate 0.8 K/min data ■ CL strength curve log-log plot when the peak integration value is set to 8.28E+8 cts/g *For more details, please download the PDF or feel free to contact us.

  • Business Intelligence and Data Analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration